| 3.09.2010 |
Dear Customers!
|
Please note that on the 7th of September there can be irregularities in availability of www.acelaboratory.com and www.pc-3000flash.com websites because of technical works.
Feel free to contact our Technical Support engineers if you have any requests for activations/licences. Please accept our apologies for the inconveniences.
|
| 2.09.2010 |
Top 5 Guru bonus!
|
Within a short period of time Global Solution Centre for PC-3000 Flash SSD Edition has proved to be a very useful solution for recovering data from flash memory drives and SSD. Now you can solve many cases within 3-5 minutes which is incredible progress in flash memory data recovery!
We notice your active participation in sharing the ready solutions of flash memory data recovery cases and would like to thank the most active persons who achieve the highest ratings.
By the end of 2010, Top 5 participants who reach the highest levels in providing the biggest numbers of unique solutions will be awarded. Each ready solution uploaded to Global Solution Centre is worth 5 ACEeuro, it means that you'll be able to use such virtual ACEeuros in acquiring any PC-3000 equipment or Technical Support service.*
Top 5 participants are displayed in the home page of Global Solution Centre.
________
* - ACEeuro = 1 Euro and can be used only for the purchase of any ACE products or service. If you decide not to use the bonus, no cash will be sent - but still you will be announced as Top 5 guru winner.
|
| 12.08.2010 |
What do you need to create something new, that nobody has?
|
The answer is simple: a team of brilliant engineers, one year and a half of research works in Solid State Drive technology.
The result is: PC-3000 Flash SSD Edition New!
The profit is: SSD in your business
All authorized users can get access to this product right now! More about new version...
|
| 15.06.2010 |
COMING SOON!
|
Our company has developed immensely powerful product - PC-3000 Flash SSD Edition - which will support Solid State Drives (SSD) and flash drives.
The great potential of SSD technology along with ever-growing demand for SSD are bound to make data recovery from SSD the business of future. With PC-3000 Flash SSD Edition you can grab the opportunity to succeed in it very soon!
You can get all technical details about its usage, features and performance capabilities in our website www.pc-3000flash.com
All customers who have purchased or will purchase PC-3000 Flash product till the 1st of July, 2010 will get complete functionality of PC-3000 Flash SSD Edition product FREE OF CHARGE.
You can obtain all details about the cost, delivery conditions by your personal sales managers or at sales@acelab.ru
Keep up with the data recovery progress!
|
| 15.06.2010 |
A new version of our www.pc-3000flash.com website dedicated to the new product PC-3000 Flash SSD Edition has been released.
|
We invite everybody to visit our new resource and estimate the vast opportunities of our new product. We will highly appreciate any types of your feedbacks e-mailed to sales@acelab.ru
|
| 23.04.2010 |
Special adapters for PC-3000 Flash are included into the delivery suite.
|
Now the special adapters which significantly increase the list of supported NAND memory chips are available.
These new PC-3000 Flash adapters are intended to adapt LGA-52, TSSOP-48 packages and devices with NAND Flash interface with random location of contacts to PC-3000 Flash Reader panel.
To use the adapter, you should solder memory chip on the proper adapter, then install this construction into the Reader panel.
When you solder microchips in LGA-52, TSSOP-48 packages, it is necessary to follow the identification of the first output. If outputs are located randomly, you should use PIN MAP adapter and follow the pinout scheme of the adapter as shown in the memory chip data sheet.
Right now, this set of adapters is supplied in PC-3000 Flash delivery suite on default.
|
| 26.03.2010 |
We have released the new version of PC-3000 Flash ver. 3.0.4! It has a lot of new features and very useful additions.
|
There are a lot of enhancements in the new version, ECC errors correction algorithm support is allowed, new modes of operation and new controllers algorithms are added.
The full list of overpatchings you can find here...
RAW recovery mode is enhanced greatly: file structure analysis which allows to improve recovery quality for media with fatal damages of file system and recognize the size, types and
integrity of the files is appended. This mode in the context of "raw recovery" shows more exact result, than usual "Search by GREP", which was available in the previous versions.
Now we are working on improving manual which will describe all new possibilities of PC-3000 Flash ver. 3.0.4.
New version of manual will be available in the nearest time.
|
| 26.03.2010 |
Epoch-making event in flash media data recovery!
|
There is nothing similar in the world! Now recovering data from flash drives becomes easier than ever before. PC-3000 Flash Global Solution Centre is the place where you can find and share the most efficient ways to solve your flash media data recovery cases. From this moment you don't need to spend your valuable time for solving many cases, you just find the solution that is recognized the quickest and most reliable way to get data of your customers!
- Free: it is free for all customers who own PC-3000 Flash tool
- Easy: Global Solution Centre is the best assistant in your everyday job
- Professionalism: You have more opportunities in raising your professionalism
- Choice: All users can find a great deal of solutions for their cases
- Efficient: You can do your job much more efficient
- Experience: The biggest group of true professionals share their knowledge and experience with you
- Automatic: You save your time and efforts
Here (pdf, 1.55 Mb) you can read about our Global Solution Centre, understand more details about features and opportunities you obtain with it.
|
| 25.03.2010 |
A new version of flash reader device inside PC-3000 Flash hardware-software tool is developed.
|
Inside PC-3000 Flash tool a new version of PC Flash Reader V2.0. device is introduced. It allows to control the condition of the lines which potentially can influence the operations with memory chip. This opportunity helps to work with all memory chips critical to output status.
More...
|
| 18.09.2009 |
The new version of PC-3000 Flash ver. 2.2 is available now!
|
It has user-friendly changes in the interface and convenient algorithms. See more...
|
| 10.08.2009 |
New version of PC-3000 Flash 2.1 ver. is released!
|
The new PC-3000 Flash has many additions and improvements. We added hardware support of memory chips with random page size, appended the information about new memory chips including memory chips supporting 8K page size, introduced new algorithms (SM321QF AC, AU6986, AU6983, SK6211, SK6281, SM267LT etc.) and other enhancements which you may see here...
If you have any questions about it, you may request it to ts2@acelab.ru or sales@acelab.ru.
|
| 29.06.2009 |
Complete version 2.0.1. of PC-3000 Flash is available now!
|
Attention!
Those users who have installed the beta version 2.0.1. must download and install the complete version 2.0.1!
The list of eliminated errors:
- the error of collecting information mode. This error in the previous version didn't allow to collect data in the task with the chips which consist of several parts.
- the bug that occurred when you used the built logical drive.
- incorrect display of last sector result.
Note:
- You need to start with the first empty memory chip task in order to do the loading of external dumps.
|
| 25.06.2009 |
The new version of PC-3000 Flash (version 2.0.1) is on beta testing stage now!
|
We have considerably increased the speed of all operations since the previous version, now the software works faster and needs much less free space than before. The new version supports microchips with the size not multiple of 528, we have added new algorithms for iCreate and SM325 controllers and have done great improvements which you may see here...
|
| 04.05.2009 |
PC-3000 Flash at ACE conference in Moscow
|
On the 22-24th of April the annual ACE conference for Russian users was held in the Moscow region, Russia. 107 participants took part in our «Flash Data Recovery for everybody» seminar and the conference itself organized in two sections «Data Recovery Technologies today» and «HDD Repair Technologies».
Here...
|
| 29.04.2009 |
Free training video on PC-3000 Flash
|
Free training video on recovering flash based storage devices by the PC-3000 Flash hardware-software solution are available! You may see what else you can do in your business to recover the damaged flash drives as efficiently as possible.
If you have any other questions about PC-3000 Flash, please feel free to contact us at sales@acelab.ru
|
| 25.03.2009 |
New version 1.6.3 of PC-3000 Flash is released!
|
You can see the new features and enhancements here...
|
| 02.03.2009 |
Revolutionary new concept in flash data recovery!
|
Nobody in the world has done it yet! New version of PC-3000 Flash changes all concepts about recovering data from flash memory devices. It has been available for all PC-3000 Flash users since yesterday and we have already received a great deal of admiring comments from our customers who have downloaded the new version.
Compare what you CAN have and what you DO have now! New version 1.6.1 is available in the update boxes of all official users of PC-3000 Flash. Read more...
|
| 25.12.2008 |
New website www.pc3000flash.com is launched!
Merry Christmas and Happy New Year to all our customers!
|
We earnestly wish you success in your business, harmony in your families and joy in your life.
There is a sign in Russia, the way you meet New Year, the same way you will spend it. We are meeting 2009 year with significant positive steps forward opening a new website for the new high-end PC-3000 Flash solution.
We have tailored all possibilities to your needs and have developed the unique world-class product for flash data recovery. This turn-key solution opens the new opportunities for your business making you at the cutting edge of your rivals. Our main aim is to give you as many advantages among your competitors as possible, that's why research and development works do not stop in ACE Laboratory company for a single day. Flash data recovery is the business of future and we make all our efforts to to help you stay Number One in your country.
We thank all our valued customers for their recommendations and advises, loyalty and high appreciation of our inventions.
Kind regards,
ACE Laboratory team
|
| 09.12.2008 |
New 1.5 version of PC-3000 Flash is released!
|
It has become much more automatic, functional and efficient.
Changes and the additions for 1.5. version of PC-3000 Flash software.
1. One of the basic changes in version 1.5. is the mode of automatic determination of the necessary sequence of operations to prepare the results of task for the analysis and the execution of this sequence.
2. The mode consists of the following elements:
- automatic determination and the elimination of mixing through the bytes in the initial results of reading or of the results of preliminary preparation;
- automatic determination and the elimination of inversion in the initial results of reading or in results of preliminary preparation;
- the automatic determination of the nonstandard structure of the task sector in the initial results of reading or the results of preliminary preparation and bringing them to the standard form. As the standard form within the framework of PC-3000 flash, the size of page 512 + 16. is considered;
- automatic determination and the elimination of the characteristic "Interleave" in the initial results of reading or in the results of preliminary preparation;
- the automatic determination of the need for additional conversions in the initial results of reading or the results of preliminary preparation and the fulfillment of these operations;
- the complex mode, which includes the above-enumerated operations in the specific sequence with the automatic fulfillment of all necessary operations.
The elements of mode are accessible for the individual fulfillment in the group "Methods of study". For the application towards the result, it is necessary to isolate it in the group "Results of preliminary preparation" or in the group "Microcircuits of memory", if it is necessary to apply method to the initial dumps. The methods of this group make possible to estimate the need of fulfilling various operations with the preparation of task for the direct fulfillment of analysis.
In this version the described mode is combined with the mode of Autodetermination, which considerably enlarges the possibilities of earlier one. In this case the list of the carried out operations can be changed by necessity with the mode's starting.
If the method "Restorations by the controller" did not yield positive results, or the required controller did not prove to be in the base of complex, you should start the mode of Autodetermination on the group "Microcircuits of memory" immediately after the reading of all microcircuits of task.
Data collection mode also includes the elements of the mode of the automatic determination of the necessary operation sequence for the preparation of the results of task for the analysis, this made possible to increase authenticity and quality of gathered information.
After the completion of data collection mode the obtained result remains in the folder "Collection of information" in the tree of the task results.
It can be arbitrarily removed or transmitted to specialized FTP any moment by PC-3000 Flash itself.
To do this you need to mark the necessary result of the collected data and select in the falling out menu point "Send to FTP". The parameters FTP communicate individually with reach other after Technical Support Service has obtained those letters with the indication of the size of the extracted file.
Other additions and the change:
- error in method "Number of block type 0 [0000]"is corrected;
- the possibility to use a mask in the method "Number of block type 0 [0000]" is added;
- method "Translator the type of 3 MemoryStick" is completed;
- the mode of auto-analysis is improved. Now it is carried out more rapid and it is more reliable;
- the mode of the data collection is changed. Its effectiveness is increased.;
- new controllers are added in the base of PC-3000 Flash.
|